The original heating ring of the barrel of the modified part should be removed.
Measure the size of the barrel, generally including the length of the circumference, calculate the required insulation cotton and estimate whether the winding position is sufficient according to the power of the original heating coil.
Wrap the insulation cotton on the barrel and fasten it with a high temperature bandage to keep the thickness of the insulation cotton at about 1.5-2.0CM. In order to make the installation more beautiful, a layer of 0.5mm insulating resin can be wrapped on the insulation cotton. board.
Wind the magnet wire on the wrapped barrel, and the wound magnet wire should be as close as possible.
Install electromagnetic heating control cabinet.